Repository logo

Performance of High-Strength Reinforced Concrete Columns Under Shock-Tube Induced Blast Loading

dc.contributor.authorHammoud, Amer
dc.contributor.supervisorAoude, Hassan
dc.date.accessioned2017-07-31T13:01:49Z
dc.date.available2017-07-31T13:01:49Z
dc.date.issued2017
dc.description.abstractAccounting for blast hazards has become one of the major concerns for civil engineers when analysing and designing structures. Recent terrorist attacks and accidental explosions have demonstrated the importance of mitigating blast effects on buildings to ensure safety, preserve life and ensure structural integrity. Innovative materials such as high-strength concrete, steel fibers, and high-strength steel offer a potential solution to increase resistance against extreme dynamic loading and improve the blast resilience of buildings. This thesis presents the results of an experimental and analytical study examining the effect of high-strength concrete, high-strength reinforcement and steel fibers on the blast behaviour of reinforced concrete columns. As part of the study, a total of seventeen reinforced concrete columns with different design combinations of concrete, steel fibers, and steel reinforcement were designed, constructed, and tested under gradually increasing blast loads using the University of Ottawa shock-tube facility. Criteria used to assess the blast performance of the columns and the effect of the test variables included overall blast capacity, mid-span displacements, cracking patterns, secondary fragmentation, and failure modes. The effect of concrete strength was found to only have a moderate effect on the blast performance of the columns. However, the results showed that benefits are associated with the combined use of high-strength concrete with steel fibers and high-strength reinforcement in columns tested under blast loads. In addition to the experimental program, a dynamic inelastic single-degree-of-freedom analysis was performed to predict the displacement response of the test columns. A sensitivity analysis was also conducted to examine the effect of various modelling parameters such as materials models, DIFs, and accumulated damage on the analytical predictions.en
dc.identifier.urihttp://hdl.handle.net/10393/36450
dc.identifier.urihttp://dx.doi.org/10.20381/ruor-20730
dc.language.isoenen
dc.publisherUniversité d'Ottawa / University of Ottawaen
dc.subjectBlasten
dc.subjectShock-tubeen
dc.subjectColumnsen
dc.subjectReinforced concreteen
dc.subjectHigh-strength concreteen
dc.subjectHigh-strength steelen
dc.subjectSteel fibersen
dc.subjectSeismic detailingen
dc.subjectSDOFen
dc.titlePerformance of High-Strength Reinforced Concrete Columns Under Shock-Tube Induced Blast Loadingen
dc.typeThesisen
thesis.degree.disciplineGénie / Engineeringen
thesis.degree.levelMastersen
thesis.degree.nameMAScen
uottawa.departmentGénie civil / Civil Engineeringen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail ImageThumbnail Image
Name:
Hammoud_Amer_2017_thesis.pdf
Size:
19.64 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail ImageThumbnail Image
Name:
license.txt
Size:
6.65 KB
Format:
Item-specific license agreed upon to submission
Description: