Repository logo

Development of a Human Activity Recognition System Using Inertial Measurement Unit Sensors on a Smartphone

Loading...
Thumbnail ImageThumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Université d'Ottawa / University of Ottawa

Abstract

Monitoring an individual’s mobility with a modern smartphone can have a profound impact on rehabilitation in the community. The thesis objective was to develop and evaluate a third-generation Wearable Mobility Monitoring System (WMMS) that uses features from inertial measurement units to categorize activities and determine user changes-of-state in daily living environments. A custom suite of MATLAB® software tools were developed to assess the previous WMMS iteration and aid in third-generation WMMS algorithm construction and evaluation. A rotation matrix was developed to orient smartphone accelerometer components to any three-dimensional reference, to improve accelerometer-based activity identification. A quaternion-based rotation matrix was constructed from an axis-angle pair, produced via algebraic manipulations of acceleration components in the device’s body-fixed reference frame. The third-generation WMMS (WMMS3) evaluation was performed on fifteen able-bodied participants. A BlackBerry Z10 smartphone was placed at a participant’s pelvis, and the device was corrected in orientation. Acceleration due to gravity and applied linear acceleration signals on a BlackBerry Z10 were then used to calculate features that classify activity states through a decision tree classifier. The software tools were then used for offline data manipulation, feature generation, and activity state prediction. Three prediction sets were conducted. The first set considered a “phone orientation independent” mobility assessment of a person’s mobile state. The second set differentiated immobility as sit, stand, or lie. The third prediction set added walking, climbing stairs, and small standing movements classification. Sensitivities, specificities and -Scores for activity categorization and changes-of-state were calculated. The mobile versus immobile prediction set had a sensitivity of 93% and specificity of 97%, while the second prediction set had a sensitivity of 86% and specificity of 97%. For the third prediction set, the sensitivity and specificity decreased to 84% and 95% respectively, which still represented an increase from 56% and 88% found in the previous WMMS. The third-generation WMMS algorithm was shown to perform better than the previous version in both categorization and change-of-state determination, and can be used for rehabilitation purposes where mobility monitoring is required.

Description

Keywords

human, activity, recognition, biomechanics, biomedical, mechanical, engineering, quaternion, smartphone, rehabilitation

Citation

Related Materials

Alternate Version