The time of flight method applied to 2.37 MeV neutrons.
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
University of Ottawa (Canada)
Abstract
A time of flight system using an associated particle detector was developed for use with DD neutrons of 2.37 MeV. As part of this system a new method of neutron gamma discrimination based on the Owen principle was developed; this method distinguishes 0.5 MeV neutrons from a very wide energy range of gamma rays. This apparatus was then used to measure the angular distributions of the neutrons scattered from the ground state and the 0.845 MeV state of Fe56.
Description
Keywords
Citation
Source: Masters Abstracts International, Volume: 45-06, page: 3179.