Reversibility of artifacts of fluid volume measurements by bioimpedance caused by position changes during dialysis

dc.contributor.authorFenech, M
dc.contributor.authorJaffrin, M Y
dc.contributor.authorMalmen, U
dc.date.accessioned2021-05-26T19:32:45Z
dc.date.available2021-05-26T19:32:45Z
dc.date.issued2002
dc.description.abstractThe effect of temporary position changes, sitting up from supine, on extracellular (ECW) and intracellular (ICW) resistances and fluid volumes calculated from whole body bioimpedance using a Xitron 4200 impedancemeter was investigated on 8 patients during dialysis for a total of 11 tests. It was found that ECW resistance decreased instantaneously by an average of 2.3% when the patient sits up, due to plasma and interstitial fluid shift into the legs which decreases leg resistance, the major contributor to total resistance. This drop in resistance is incorrectly interpreted by the device as an increase in ECW volume which averages 235 ml. But this effect is completely reversible and both ECW resistance and fluid volume rapidly resume their normal course when the patient returns to his initial position. No significant variation in ICW resistance was observed in any of the patients at the position change. We conclude that segmental impedance, which has been proposed to minimize this artifact, is not advisable in dialysis monitoring and that it is simpler to ignore or switch off measurements during the position change so that later data are not affected by it.en_US
dc.identifier.doi10.1177/039139880202500308en_US
dc.identifier.issn0391-3988en_US
dc.identifier.urihttp://hdl.handle.net/10393/42206
dc.identifier.urihttps://doi.org/10.20381/ruor-26428
dc.language.isoenen_US
dc.subjectAgeden_US
dc.subjectArtifactsen_US
dc.subjectExtracellular Spaceen_US
dc.subjectFemaleen_US
dc.subjectFluid Shiftsen_US
dc.subjectHumansen_US
dc.subjectMaleen_US
dc.subjectMiddle Ageden_US
dc.subjectPostureen_US
dc.subjectElectric Impedanceen_US
dc.subjectRenal Dialysisen_US
dc.titleReversibility of artifacts of fluid volume measurements by bioimpedance caused by position changes during dialysisen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail ImageThumbnail Image
Name:
Reversibility of artifacts of fluid volume measurements by 3 bioimpedance caused by position changes during dialysis.pdf
Size:
344.46 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail ImageThumbnail Image
Name:
license.txt
Size:
4.92 KB
Format:
Item-specific license agreed upon to submission
Description: