Repository logo

Measuring sit-to-stand timing variability over time using under mattress pressure sensor technology

dc.contributor.authorGrant, Theresa
dc.contributor.authorJoshi, Vilas
dc.contributor.authorTaylor, Matthew
dc.contributor.authorKnoefel, Frank
dc.contributor.authorSveistrup, Heidi
dc.contributor.authorBilodeau, Martin
dc.contributor.authorJutai, Jeffrey
dc.date.accessioned2015-04-01T13:50:03Z
dc.date.available2015-04-01T13:50:03Z
dc.date.created2014
dc.date.issued2014
dc.description.abstractGetting out of bed is a fundamental activity of daily living and one that supports independent living. Under mattress pressure sensor technology represents a way to monitor changes in this basic but critical mobility task among older adults at risk of institutionalization. However, little is known about normal variations in this ability over time in the home context. This study used under mattress pressure sensors to measure and analyze the variability of sit-to-stand (STS) timing in a community-dwelling older adult. A pressure-sensitive mat was installed in the participant’s home and left in place to collect information over a period of nine months. A processing algorithm was developed to extract the STS phase of the first morning bed exit from which STS time could be measured. STS timing data were visualized using a histogram and analyzed for trends over the extended period using nonparametric regression and wavelet analysis. Results indicate that the analytical methods used were able to identify trends in STS timing as well as highlight deviations. The ability to collect and analyze the variability of STS timing using this pressure sensitive technology combined with the analysis methodology provides clinicians with a way to assess mobility remotely in the home setting.
dc.description.sponsorshipCanadian Institutes of Health Research (CIHR FR # 108892); NSERC; Carleton University
dc.identifier.citationGrant, T., Joshi, V., Taylor, M., Knoefel, F., Sveistrup, H., Bilodeau, M., & Jutai, J. (2014, June). Measuring sit-to-stand timing variability over time using under mattress pressure sensor technology. In Medical Measurements and Applications (MeMeA), 2014 IEEE International Symposium on (pp. 1-5). Institute of Electrical and Electronics Engineers.
dc.identifier.doi10.1109/MeMeA.2014.6860083
dc.identifier.urihttp://hdl.handle.net/10393/32191
dc.language.isoen
dc.rights© 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
dc.subjectpressure sensors
dc.subjectpatient monitoring
dc.subjectbed exit
dc.subjectsit-to-stand
dc.subjectvariability
dc.subjecthome context
dc.titleMeasuring sit-to-stand timing variability over time using under mattress pressure sensor technology
dc.typeConference Proceeding

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail ImageThumbnail Image
Name:
MeMeA 2014 FINAL_Apr 1.pdf
Size:
616.37 KB
Format:
Adobe Portable Document Format
Description:
Grant 2014 - MeMeA

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail ImageThumbnail Image
Name:
license.txt
Size:
4.92 KB
Format:
Item-specific license agreed upon to submission
Description: