Repository logo

Two experiments involving the detection of 14 MeV neutrons.

Loading...
Thumbnail ImageThumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

University of Ottawa (Canada)

Abstract

Part I. An existing Time-of-Flight system was improved so that 14 MeV neutrons, after striking an oxygen target, could be detected with sufficient resolution to indicate whether the state excited was at 6 or 7 MeV. The new data obtained concerning angular distributions was compared with previous data, and agreement was sought with several theoretical models. Part II. Several detection devices, suitable for a spectrometer, which could operate with neutrons up to 14 MeV of energy were tried. One of the devices, a Li6I(Eu) crystal, cooled to the temperature of liquid air, proved quite promising. Once the difficulties of obtaining a good crystal are overcome, it appears that this device is quite suitable for studying neutron induced reactions in shielding materials.

Description

Keywords

Citation

Source: Masters Abstracts International, Volume: 45-06, page: 3179.

Related Materials

Alternate Version